As you would expect from the leader in Hydrogen Sulfide gas
technology, Texas Analytical Controls is proud to announce its latest and most reliable
LEL Transmitter -- Model 201MS.
The 201MS can be ordered with either a catalytic bead/diffusion sensor or with infrared
technology.
The electronics are housed in an explosion-proof enclosure suitable for Class I, Division
I, Groups B, C, and D. This rating is maintained throughout the normal operation as well
as calibration of the transmitter. Calibration is initiated by a small magnet without
opening the cover. Area declassification is not required.
Calibration of the 201MS is fast, simple and reliable. The only 2 items required for
calibration are a known standard source of gas and a small magnet. While holding the
magnet briefly over the "CAL" label on the front panel, a letter "C"
will start flashing on the display, signifying the start of the calibration cycle. Two to
four minutes later, the "C" ceases to flash and the program automatically
adjusts the internal gain of the unit to the predefined concentration stored in the
EEPROM. The display will then reflect the correct concentration of gas applied. A minute
later, the alarm relays and the 4/20 mA output become active again. Calibration is
complete, no pots to adjust, no ZERO or SPAN voltages to remember and set.
The gas concentration is displayed on a large 3 1/2" digital display. A 4/20 mA
output is provided which can be used with any computer or SCADA system in a control
room.
Optional are two alarm relays for local level control at the sensor site. This reduces the
cost for running additional cables for local alarms.
Every significant parameter in the Model 201MS is field programmable. From range, alarm
set-points, latching - non-latching status of alarms, to calibration gas concentration.
Operators can program all these features with ease in the field.
When used with aTAC monitoring system, 12 VDC power will be provided by the monitor. If
used as stand-alone unit, the 201MS can be powered from 12 to 24 VDC.
TAC's unique sensor can work in harsh environments present in oil rigs or in gas plants
without affecting its performance.
Specifications:
| Detection
Method: Catalytic bead/ diffusion or Infrared. |
Sensor
Life: Guaranteed: One year; expected life three to five years in air. |
| Humidity
Range: No effect up to 100%, non-condensed. |
Signal
Output: 4-20 mA |
| Response
Time: 0-50% LEL in 10 seconds with 100% LEL applied. 1-90% LEL in 30 seconds with 100% LEL applied. |
Sensitivity: No loss of sensitivity or response time due to lack of exposure to LEL; no poisoning effect due to 100% LEL exposure. |
| Clearing
Time: 80% clear in less than 40 seconds; 100% clear in less than 3 minutes. |
Electrical
Classification: Class I, Div. I; Groups B, C & D. |
| Operating Temp.: -30º F to + 150º F |
Interconnect
Wiring: 18 gauge, 3 conductors up to 500 ft. 16 gauge, 3 conductors up to 1,600 ft. 14 gauge, 3 conductors up to 3,000 ft. |
Ordering Information:
|
|
|
Also Available: Click here for more information
|
|
|